Electronics for the CREAM calorimeter and hodoscopes
Year: 2005
Type: article
Abstract: The electronics used for the CREAM calorimeter trigger and signal readout are based on 80 (32-channel) VA32-HDR2/TA32C chips digitized by 80 (12-bit) LTC1400 ADCs.The hodoscope electronics use 144 (16-channel) CR-1.4A chips digitized by 72 (16-bit) MAX1133 ADCs.The basic characteristics, such as noise level, dynamic range, linearity, and gain of both systems were measured in the laboratory.The results confirm that the design goals of the CREAM experiment could be achieved.
Authors: M. H. Lee, O. Ganel, He Guo, L. Lutz, A. Malinine, R. Sina, Shafi Syed, Jack Wu, M. H. Lee
Institution: University of Maryland, College Park
Language: English
Subfield: Nuclear and High Energy Physics
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W198843367