Year: 2012
Type: article
Abstract: Reliable microaneurysm detection in digital fundus images is still an open issue in medical image processing. We propose an ensemble-based framework to improve microaneurysm detection. Unlike the well-known approach of considering the output of multiple classifiers, we propose a combination of internal components of microaneurysm detectors, namely preprocessing methods and candidate extractors. We have evaluated our approach for microaneurysm detection in an online competition, where this algorithm is currently ranked as first, and also on two other databases. Since microaneurysm detection is decisive in diabetic retinopathy (DR) grading, we also tested the proposed method for this task on the publicly available Messidor database, where a promising AUC 0.90 ± 0.01 is achieved in a "DR/non-DR"-type classification based on the presence or absence of the microaneurysms.
Institution: University of Debrecen
Language: English
Topic: Retinal Imaging and Analysis
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W1996151979
