X-ray–optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser
Year: 2012
Type: article
Abstract: X-ray–optical pump–probe experiments at the Linac Coherent Light Source (LCLS) have so far been limited to a time resolution of 280 fs fwhm due to timing jitter between the accelerator-based free-electron laser (FEL) and optical lasers. We have implemented a single-shot cross-correlator for femtosecond x-ray and infrared pulses. A reference experiment relying only on the pulse arrival time information from the cross-correlator shows a time resolution better than 50 fs fwhm (22 fs rms) and also yields a direct measurement of the maximal x-ray pulse length. The improved time resolution enables ultrafast pump–probe experiments with x-ray pulses from LCLS and other FEL sources.
Source: Applied Physics Letters
DOI: 10.1063/1.3695163
Institutions: SLAC National Accelerator Laboratory, Linac Coherent Light Source, Technische Universität Berlin, Center for Free-Electron Laser Science, Max Planck Institute for Nuclear Physics, Max Planck Institute for Medical Research, Max-Born-Institute for Nonlinear Optics and Short Pulse Spectroscopy
Language: English
Subfield: Atomic and Molecular Physics, and Optics
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: hybrid
OpenAlex ID: W2000216091