Year: 2009
Type: article
Abstract: Sampling and Analytical MethodologySamples were taken using 24 internally Teflon-coated PVC 12 litre GO-FLO Samplers (General Oceanics Inc.) mounted on an all-titanium frame.This frame was connected to a 17.7 mm diameter Kevlar hydrowire with seven independent internal signal/conductor cables (Cousin Trestec S.A.) and controlled from onboard.Each GO-FLO sampler had a special ultraclean all-teflon PTFE valve (Cole Parmer; PN A-06392-31) installed.Samples for trace metal analysis were collected from the GO-FLO bottles in a class 100 clean room environment.The water was filtered over a 0.2 μm filter cartridge (Sartrobran-300, Sartorius) under pressure (1.5 atm) of (in-line prefiltered) nitrogen gas exerted via a special connector instead of the regular air bleeding valve at the top of each GO-FLO sampler.Sub-samples for Al were taken in cleaned LDPE sample bottles (125 mL) from each GO-FLO bottle.All sample bottles were rinsed five times with the sample seawater.Analyses of dissolved Al were based on a method developed by Resing and Measures (1994).Samples were stored in a refrigerator (4 °C) and analysed usually within 24 h after sampling but always within 36 h.Samples were acidified at least 1 h before analyses with 12 M ultraclean HCl (Baseline® Hydrochloric Acid, Seastar Chemicals Inc.) to a pH of 1.8.In a flow injection system the samples were buffered inline to a pH of 4.8 ± 0.1 with ultraclean 0.6 M ammonium acetate buffer.This buffer was produced by diluting a saturated solution of ammonium acetate crystals to an 0.6 M solution with MQ.The pH was subsequently adjusted to 6.7 with ultraclean ammonium hydroxide.This was produced by bubbling 0.2 µm filtered high purity ammonia gas through MQ water.The buffered sample was pre-concentrated for 240 s on a Toyopearl AF-Chelate 650M (TosoHaas, Germany) column.Hereafter the column was rinsed for 60 s with MQ water to remove interfering salts.The Al was subsequently eluted from the column with 0.16 M HCl (Suprapure, Merck) during 250 s.The eluate of Al in HCl entered the reaction stream which consisted of a lumogallion (Pfaltz & Bauer) solution in 4 M ammonium acetate buffer.The 4 M buffer was produced similar to the 0.6 M buffer (see above), but with the pH adjusted to 6.8 ± 0.1 and the lumogallion was a 4.8 mM solution in MQ.The mixing of the HCl and buffer results in a reaction pH of 5.7 ± 0.1 at which an Al-Lumogallion chelate complex is formed which can be detected by its fluorescence.The complex was mixed in a 10 m reaction coil placed in a water bath of 50 °C.Hereafter a 2.5% Brij-35 (Merck) solution in MQ was added to increase the sensitivity (Resing and Measures, 1994) and mixed in a 3 m mixing coil.Afterwards the emission of the fluorescent complex was detected on a FIA-lab PMT-FL detector with a 510 until 580 nm emission filter and a 480 until 490 nm excitation filter.Concentrations of Al were calculated in nanomol.L-1 from the peak heights.The system was calibrated using standard additions from a 5000 nM Al stock solution (Fluka) to filtered acidified seawater of low Al concentration that was collected in the Arctic Ocean.A six-point calibration line (0, 1, 2, 4, 8 and 16 nM standard additions) and blank determination were made every day.The 3 lowest points (0, 1 and 2 nM) of the calibration line were measured in triplicate and the 3 highest points (4, 8 and 16 nM) in duplicate in order to add more weight to the lower part of the calibration line.The blank was determined by plotting the signals of increasing pre-concentration times (30, 60, 120, 210 and 300 seconds) of the water also used for the calibration.A line was fitted through these data points and the intercept of the line taken as the blank, which was usually below 0.2 nM.If the blank was greater than 0.2 nM, the analysis run was stopped.Subsequently the system was cleaned and the blank reanalysed with freshly made sampling buffer until the blank value was below the 0.2 nM limit.The limit of detection, defined as three times the standard deviation of the lowest concentration observed, was 0.15 nM.The FIA system was cleaned every day by rinsing with a 0.5 M HCl solution.
Authors: H. J. W. de Baar, Rob Middag
Language: English
Subfield: Oceanography
Field: Earth and Planetary Sciences
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W201170592
