Work

Method development based on molecularly imprinted polymers for the selective extraction of organic compounds in complex aqueous matrices

Year: 2010
Type: dissertation
Abstract: Contamination of water from organic compounds in low concentrations such as triazines \nherbicides and estrogens and the fact that due to complex matrix effect, the compounds \nare not easy to determine which call for sample preparation approaches such as MIPSE – \nMMLLE. A selective extraction method based on the combination of microporous \nmembrane liquid-liquid extraction (MMLLE) and molecularly imprinted polymers \n(MIPs) was developed and applied to the extraction of 17 β-estradiol and selected \ntriazines herbicides in complex aqueous samples. These pollutants were extracted from \naqueous complex samples through the hydrophobic porous membrane that was \nimpregnated with toluene, which also formed part of the acceptor phase. In the acceptor \nphase, the compounds were re-extracted onto MIP particles. The extraction technique \nwas optimised for the amount of MIP particles in the organic acceptor phase, extraction \ntime, and type of organic acceptor solvent and desorption solvent. Triazines herbicides \n(simazine, atrazine and propazine) and estrogenic compound (17 β-estradiol) were used \nas model compounds in this study. HPLC-UV was used for the determination of these \norganic compounds. \nAn extraction time of 90 minutes and 10 mg of MIP were found to be optimum \nparameters for triazines extraction. Toluene as the acceptor phase was found to give \nhigher triazines binding onto MIP particles compared to hexane and combinations of \ndiethyl ether and hexane. 90% methanol in water was found to be the best desorption \nsolvent compared to acetonitrile, methanol and water. Higher MIP mass (30 mg) was \nused for 17 β-estradiol (E2) because of poor binding kinetics. An extraction time of 60 \nminutes and 90% methanol in water were adopted. Hexane: ethyl acetate (3:2) as the \nacceptor phase was found to give a stable membrane and give better partitioning of the \nE2 from the aqueous donor. In order to improve the binding of the E2 onto the MIP \nultrasound assisted rebinding was studied. \nThe developed method proved its selectivity to the extraction of complex matrices where \nclean chromatograms were obtained. Furthermore samples spiked with varying amounts \nof humic substances were also extracted and “clean” chromatograms obtained. Reference iii \nmaterials containing ametryn, prometon, prometryn, propazine, simetryn, simazine and \nterbutryn were extracted to demonstrate the validity of the developed technique. The \nresults indicated that the MMLLE – MIP could be used to reliably determine real \nsamples. The method was then applied to spiked lettuce, apple extracts and wastewater \nwhere clean chromatograms were obtained compared to MMLLE alone or to the \nmicroporous membrane liquid-liquid extraction – non imprinted polymer combination \n(MMLLE – NIP). \nThe triazine MIP showed a certain degree of group specificity and the extraction \nefficiency was 68 % for simazine, 74 % for atrazine and 69% for propazine, giving \nenrichment factors of 40, 56 and 45, respectively in deionised water. The extraction \nefficiency in apple extracts were 55%, 63% and 60% for simazine, atrazine and propazine \nrespectively. The percentage relative standard deviation in plant samples ranged from 1 \nto 15. The E2 MIP also demonstrated high selectivity although the extraction efficiencies \nand enrichments factors were low due to poor E2 binding on the MIP particles.
Author: Byron Mhaka
Language: English
Field: Chemistry
Open Access status: green
OpenAlex ID: W202221014
Cites: 102
Cited by:
Related to: 10