Potential errors in the application of mixture theory to multifrequency bioelectrical impedance analysis
Year: 1998
Type: article
Abstract: Potential errors in the application of mixture theory to the analysis of multiple-frequency bioelectrical impedance data for the determination of body fluid volumes are assessed. Potential sources of error include: conductive length; tissue fluid resistivity; body density; weight and technical errors of measurement. Inclusion of inaccurate estimates of body density and weight introduce errors of typically < +/- 3% but incorrect assumptions regarding conductive length or fluid resistivities may each incur errors of up to 20%.
Source: Physiological Measurement
Authors: L C Ward, M Elia, B H Cornish
Language: English
Subfield: Physiology (medical)
Field: Medicine