Carbon Dioxide Absorption and Desorption in Aqueous Monoethanolamine Solutions in a Rotating Packed Bed
Year: 2007
Type: article
Abstract: The absorption and desorption of carbon dioxide in aqueous monoethanolamine (MEA) was measured in a rotating packed bed of size 398 mm outside diameter, 156 mm inside diameter, and axial depth 25 mm. The effect of lean amine temperature (20 and 40 °C), peripheral rotor gravity (31 and 87 g), and various MEA concentrations were investigated. Using MEA concentrations above 30 wt % achieved lower CO 2 penetration levels. This is particularly pronounced for the 100% MEA solution. Comparison with conventional columns showed the advantages of using rotating packed beds in terms of saving size and space and efficient operation.
DOI: 10.1021/ie051104r
Language: English
Subfield: Filtration and Separation
Field: Chemical Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2036074126