Assessment of appropriate laboratory measurements to supplement the Crohn's disease activity index.
Year: 1981
Type: article
Study design: Observational Study
Abstract: The ability of 11 laboratory parameters to reflect the degree of activity of Crohn's disease, using a clinical index as reference point was compared by means of multiple stepwise regression analysis. Activity was best defined in decreasing order by orosomucoid, sedimentation rate, C reactive protein, alpha-1-antitrypsin, albumin, haematocrit, IgM, circulating immune complexes, serum iron, IgG, and IgA. The haematocrit, the only laboratory measurement in the Crohn's disease activity index developed by the National Cooperative Study Group in the USA, is less discriminant than acute phase reactants. Only three parameters-namely, orosomucoid, sedimentation rate, and C reactive protein-have a significant weight and should be complementary to a simple clinical index.
Source: Gut
DOI: 10.1136/gut.22.7.571
Authors: C Andre, L Descos, P Landais, J Fermanian
Institutions: Inserm, Pitié-Salpêtrière Hospital, Hôpital Edouard Herriot
Language: English
Topic: Inflammatory Bowel Disease
Subfield: Gastroenterology
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W2038627922