An analysis method for asymmetric resonator transmission applied to superconducting devices
Year: 2012
Type: article
Abstract: We examine the transmission through nonideal microwave resonant circuits. The general analytical resonance line shape is derived for both inductive and capacitive coupling with mismatched input and output transmission impedances, and it is found that, for certain non-ideal conditions, the line shape is asymmetric. We describe an analysis method for extracting an accurate internal quality factor (Qi), the diameter correction method (DCM), and compare it to the conventional method used for millikelvin resonator measurements, the φ rotation method (φRM). We analytically find that the φRM deterministically overestimates Qi when the asymmetry of the resonance line shape is high, and that this error is eliminated with the DCM. A consistent discrepancy between the two methods is observed when they are used to analyze both simulations from a numerical linear solver and data from asymmetric coplanar superconducting thin-film resonators.
Source: Journal of Applied Physics
DOI: 10.1063/1.3692073
Authors: M. S. Khalil, M. J. A. Stoutimore, F. C. Wellstood, K. D. Osborn
Institutions: University of Maryland, College Park, Joint Quantum Institute
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green