Abstract: This paper investigates strengthening masonry shear walls using two types fiber reinforced polymer (FRP) sheets.An experimental research program is undertaken.Masonry wall made from wire-cut clay brick specimens are tested strengthening by PET (Polyethylene Terephthalate) and CFRP (Carbon fiber reinforced polymer) sheets.Strengthening is considered on both side of the wall to ensure uniformity and symmetrical stiffness of the wall.Static tests are carried out on seven masonry panels, under a combination of vertical preloading, and in-plane horizontal shear loading.The mechanisms by which load was carried were observed, varying from the initial, uncracked state, to the final, fully cracked state.The results demonstrate that a significant increase of the in-plane shear capacity of masonry can be achieved by bonding with PET and CFRP sheets to the surface of masonry walls.The experimental data were used to assess the effectiveness of the strengthening of one FRP over the other and also the percent of gross area covered by the FRP sheets.Subsequently suggestions are made to allow the test results to be a reasonable source of guideline in the design of strengthening for masonry structures.