Work

Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging

Year: 1997
Type: review
Abstract: Three major models (from Tofts, Larsson, and Brix) for collecting and analyzing dynamic MRI gadolinium-diethylene-triamine penta-acetic acid (Gd-DTPA) data are examined. All models use compartments representing the blood plasma and the abnormal extravascular extracellular space (EES), and they are intercompatible. All measure combinations of three parameters; (1) kPSp is the influx volume transfer constant (min-1), or permeability surface area product per unit volume of tissue, between plasma and EES; (2) ve is the volume of EES space per unit volume of tissue (0 < ve < 1); and (3) K(ep), the efflux rate constant (min-1), is the ratio of the first two parameters (k(ep) = kPSp/ve). The ratio K(ep) is the simplest to measure, requiring only signal linearity with Gd tracer concentration or, alternatively, a measurement of T1 before injection of Gd (T10). To measure the physiologic parameters kPSp and ve separately requires knowledge of T10 and of the tissue relaxivity R1 (approximately in vitro value).
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W2072626310
FWCI: 3.869
Cites: 52
Cited by: 1,510
Related to: 10