Work

Site-Specific in vivo Targeting of Magnetoliposomes Using Externally Applied Magnetic Field

Year: 2000
Type: article
Abstract: Human serum albumin labeled with technetium-99m was encapsulated together with magnetite particles into phosphatidylcholine/cholesterol liposomes. In order to investigate the stability of this complex and its ability to be used for magnetic drug targeting, the in-vivo distribution after intravenous administration in rats was estimated. For in-vivo targeting an SmCo permanent magnet with intensity approximately 0.35 T was attached near the right kidney. Difference between the relative radioactivity in the magnetically targeted right kidney (25.92+/-5.84%) and non-targeted left kidney (0.93+/-0.05%) is sufficiently high for relevant clinical applications.
Language: English
Subfield: Biomaterials
Open Access status: hybrid
Estimated APC paid: $2,712
OpenAlex ID: W2090389716
FWCI: 0.653
Cites: 18
Cited by: 61
Related to: 9