Estimation of Missing Data in Multi-channel Physiological Time-series by Average Substitution with Timing from a Reference Channel
Year: 2011
Type: conference-paper
Abstract: The Computing in Cardiology Challenge 2010 was to develop a computer algorithm for reconstructing missing sections of physiological data.For cardiac related signals our algorithm obtained beat timings from a reference timing channel. Missing beats were estimated from the average of non-missing beats. ECG derived respiration was used for missing respiratory data. Score for event 1 was 59 and for event 2 was 72.Good scores were achieved despite beat-to-beat reconstructions that lacked important physiological detail, serving to illustrate that it is essential to evaluate the clinical impact of reconstruction algorithms.
Source: Computing in cardiology
Institutions: Freeman Hospital, Newcastle University
Language: English
Topic: ECG Monitoring and Analysis
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2095652113