Work

The Nordic Expert Group for Criteria Documentation of Health Risks from Chemicals : 138. Microbial volatile organic compounds (MVOCs)

Year: 2006
Type: report
Abstract: Microbial volatile organic compounds (MVOCs) consist of a variety of compounds (mainly alcohols, ketones, terpenes, esters, aldehydes, sulphur and nitrogen compounds) formed as side-products in the primary and secondary metabolism of fungi and bacteria. More than 200 compounds have been identified as MVOCs in laboratory experiments, but none can be regarded as exclusively of microbial origin or specific for certain microbial species. Thus, these compounds also have many other, often much stronger, sources than microbial metabolism in the environment. Furthermore, the techniques chosen for sampling and analysis will effect which MVOCs are detected. In many cases, the typcially 10-15 compounds analysed have been selected beforehand based on previous investigations as well as existing analytical facilities. In this review, the basic physical and chemical properties of 96 typical MVOCs have been summarised. Of these, the 15 MVOCs listed below have most often been analysed and reported in buildings with moisture and microbial damage and sometimes in occupational settings (in agriculture or compost facilities). These were also the MVOCs for which the toxicological and exposure data were gathered in this report: 2-Methyl-1-propanol 1-Octen-3-ol 3-Octanone 3-Methyl-1-butanol 2-Octen-1-ol 2-Methylisoborneol 3-Methyl-2-butanol 3-Methylfuran 2-Isopropyl-3-methoxy-pyrazine 2-Pentanol 2-Hexanone Geosmin 3-Octanol 2-Heptanone Dimethyl disulphide In studies with quantitative MVOC results, single MVOC levels have ranged from a few ng/m3 up to 1 mg/m3 both in indoor and work environments, however, quantitative data from work settings are limited to compost facilities. The comparable data on MVOC levels in the environment published so far are inadequate for drawing reliable conclusions on the MVOC exposure. The main exposure route for MVOCs is absorption through the lungs. Typical MVOCs are rapidly metabolised and excreted in the urine and bile. Generally, MVOCs do not accumulate in tissues to any great extent. The toxicological database is poor for the 15 listed MVOCs. In epidemiological studies on buildings with moisture and microbial damage, MVOCs, in addition to many other microbial agents, have been associated with unpleasant odours, eye and upper airway irritation, unspecific symptoms and even asthma-like symptoms. However, inflammatory responses of single or repeated MVOC exposures have not been unequivocally confirmed in controlled human exposure studies. The most obvious health effect of MVOC exposure is eye and upper airway irritation, due to stimulation of the trigeminal nerves (sensory irritation), which seems to be the critical effect also for many individual MVOCs although there are exceptions (2 hexanone). In human experimental exposure studies, symptoms of irritation have appeared at MVOC concentrations several orders of magnitude higher than those measured under field conditions in indoor environments. This is supported by data from animal studies. According to the database determined by the ASTM mouse bioassay, dose-dependent sensory irritation has been detected for many typical MVOCs. Assuming additivity of the sensory irritation reaction, the irritation responses anticipated from exposure to MVOC mixtures lead to the conclusion that MVOCs : as combinations and concentrations reported so far : are well below the levels needed to cause sensory irritation. Overall, considering the very low levels encountered in the MVOC context, no toxic effects besides irritation, and very seldom also this effect, are expected. On the other hand, the present document covers the toxicological data of only 15 out of more than 200 MVOCs recognised so far. Thus, the conclusions do not necessarily apply to all MVOCs, and not even for all of the 15 compounds evaluated, as there may be more potent compounds and/or other endpoints not yet evaluated. So far, attempts to recognise microbially contaminated buildings or areas, or to verify the success of remedial measures by MVOC measurements have failed because of considerable overlap of the results (both for individual MVOCs and sums of several MVOCs) between suspected and control areas. Thus, in order to identify contaminated buildings by MVOC measurements, MVOCs of purely microbial origin and/or sophisticated data handling procedures are needed.
Language: English
Open Access status: green
OpenAlex ID: W2096879811
Cites: 169
Cited by: 20
Related to: 10