Successful management of an aortoesophageal fistula caused by a fish bone – case report and review of literature
Year: 2009
Type: article
Study design: Case Report
Abstract: We report a case of aortoesophageal fistula (AEF) caused by a fish bone that had a successful outcome. Aortoesophageal fistula is a rare complication of foreign body ingestion from which few patients survive. Over one hundred cases of AEF secondary to foreign body ingestion have been documented but only seven, including our case, have survived over 12 months. Treatment involved stabilising the patient with a Sengstaken-Blakemore tube and insertion of a thoracic aortic endovascular stent-graft. Unfortunately the stent became infected and definitive open surgical repair involved removing the stent, replacing the aorta with a homograft and coverage with a left trapezius flap while under deep hypothermic arrest.
Authors: Stephen L. Kelly, Paul Peters, Murray J. Ogg, Alan Li, Bernard M. Smithers
Institutions: Princess Alexandra Hospital, The University of Queensland
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,890
Funder: Cook Medical
OpenAlex ID: W2100663675