Work

Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging

Year: 2002
Type: article
Abstract: An 8-channel receive-only detector array was developed for SENSE MRI of human brain. The coil geometry was based on a gapped element design and used ultra-high impedance preamplifiers for mutual decoupling of the elements. Computer simulations of the electric and magnetic fields showed that excellent signal-to-noise ratio (SNR) and SENSE performance could be achieved by placing the coil elements close to the head and maintaining a substantial gap between the elements. Measurements with a 1.5 T prototype coil showed a 2.7-fold improvement of the SNR averaged over the brain compared to a conventional quadrature birdcage receive coil and an average geometrical noise amplification factor (g-value) of 1.06 and 1.38 for rate-2 and rate-3 SENSE, respectively.
Language: English
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $3,680
OpenAlex ID: W2103368607
FWCI: 11.07
Cites: 15
Cited by: 192
Related to: 10