Year: 2014
Type: article
Abstract: PURPOSE: Diffusion-weighted chemical shift imaging (DW-CSI) of brain metabolites poses significant challenges associated with the acquisition of spectroscopic data in the presence of strong diffusion weighting gradients. We present a reproducible DW-CSI acquisition and processing scheme that addresses most of the potential sources of instability and provides reproducible and anatomically meaningful diffusion-weighted and apparent diffusion coefficient (ADC) metabolite maps. METHODS: A real-time navigator-based acquisition scheme was used, allowing instantaneous reacquisition of corrupted k-space data and postprocessing correction of gradient-induced phase fluctuations. Eddy current correction based on residual water resonance was implemented and improved the quality of the data significantly. RESULTS: Highly reproducible diffusion-weighted metabolite maps of three highest concentration brain metabolites are shown. The navigator-based accept/reject strategy and the postacquisition corrections improved the stability of the DW-CSI signal and the reproducibility of the resulting DW-CSI maps significantly. The metabolite ADC values could be related to the underlying tissue cellular composition. CONCLUSION: Robust investigation of DW-CSI of brain metabolites is feasible and may provide information complementary to that obtained from more sensitive but less specific methods such as diffusion tensor imaging.
Source: Magnetic Resonance in Medicine
DOI: 10.1002/mrm.25346
Institutions: Leiden University Medical Center, Mahidol University
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W2103545213