Determination of cholesterol using o-phthalaldehyde
Year: 1973
Type: article
Abstract: A simple, rapid method for the determination of cholesterol in plasma and tissue using o-phthalaldehyde is presented. Comparison of this method with the FeCl(3) method gave identical results. However, the o-phthalaldehyde determination is three times more sensitive than the FeCl(3) determination (molar extinction coefficients of 11,610 and 33,440 for FeCl(3) and o-phthalaldehyde, respectively), it takes less time to complete, and the color developed is more stable. The o-phthalaldehyde method can be used to assay free and esterified cholesterol directly after thin-layer chromatographic separation.
Source: Journal of Lipid Research
Authors: L.L. Rudel, M.D. Morris
Institutions: University of Toronto, University of Arkansas Medical Center
Language: English
Subfield: Biochemistry
Domain: Life Sciences
Open Access status: hybrid
Estimated APC paid: $3,430
OpenAlex ID: W2104010651