Shear Bond Strength of Three Adhesive Systems to Bovine Dentin
Year: 2003
Type: article
Abstract: The aim of this study was to evaluate the shear bond strength of a self-etching primer Clearfil SE Bond (CSEB) and to compare it to two five generations adhesive systems Optibond Solo Plus (OPBS) and Prime & Bond NT (PBNT). Thirty noncarious bovine incisors were embedded in acrylic resin boxes. After the exposure of dentin, the specimens were randomly divided into three groups (n = 10) according to the adhesive systems. It was constructed a cylindri- cal restoration in composite resin (Z - 100) by incremental insertion technique. The samples were thermal cycled (300 cycles: 5°C and 55°C) and subsequently the shear bond strength tests were performed on an Instron Universal machine, at 0.5 mm/min speed. The data (MPa) were submit- ted to analysis of variance using ANOVA one-way test and multiple comparison range (α = 0.05). The adhesive system OPBS presented the best mean value (21.20 ± 3.32) followed by PBNT (14.37 ± 2.62). The self-etching adhesive CSEB showed mean shear bond strength (11.00 ± 2.78) significantly lower than the other two adhesive systems tested. It can be concluded that the 5 th generation adhesive systems tested showed higher bond strength that the self-etching adhesive system.
Source: Revista de Odontologia da UNESP
Institution: Universidade Estadual Paulista (Unesp)
Language: English
Subfield: General Dentistry
Field: Dentistry
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $133
OpenAlex ID: W2111337045