Year: 2013
Type: article
Abstract: According to early examination (Vojniković, 1978) estimated, that the index of refraction for aqueous and vitreous is not the sum (1.33 or 1.66), than is for aqueous n = 1.334, and for vitreous N = 1.336. This measurements are made with Abbe's refractometer, by temperature of 33 degrees C for aqueous, and 36 degrees C for vitreous, as it's in human eye. In the principle of these results, the authors calculated the new values of cardinal points for the eye, and compared with Gullstrand's optical schematic eye. So, the refractive power for the eye F = 59.98 D, first focal length f1 = -16.67 mm and second focal length f2 = +22.27 mm
Source: PubMed
Authors: Bozo Vojniković, Ettore Tamajo
Language: English
Subfield: Ophthalmology
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2124048373