Abstract: An L-band (1.3 GHz), normal-conducting, 5-cell, standing-wave cavity that was built as a prototype capture accelerator for the ILC is being high-power processed at SLAC. The goal is to demonstrate stable operation at 15 MV/m with 1 msec, 5 Hz pulses and the cavity immersed in a 0.5 Telsa solenoidal magnetic field. This paper summarizes the performance that was ultimately achieved and describes a novel analysis of the modal content of the stored energy in the cavity after a breakdown to determine on which iris it occurred.