Investigations on Cationic Exchange Capacity and Unused Bed Zone according to operational conditions in a Fixed Bed Reactor for water lead removal by a natural zeolite
Year: 2006
Type: article
Abstract: In this study, attention has been focused on the behaviour of the Cationic Exchange Capacity (CEC) and the Unused Bed Zone (UBZ), according to the operating parameters (bed length: L, column diameter: D, particle diameter: d and fl ow rate: Q) in a Fixed Bed Reactor (FBR).The investigations are performed for a single-component study of lead on New Zealand clinoptilolite at 25 ± 1°C.The results show a constant operating CEC of 1.00 ± 0.015 meq .g -1 which is independent of the operational parameters listed above.The performance of the operations expressed as UBZ, shows an optimum for the ratio L/D (bed length and column diameter) fi xed at 18.1, for Q = 2.9 BV .h -1 (bed volume per hour) and particle diameter d = 0.38 mm (the ratio particle diameter on column diameter d/D at 0.057).This maximum performance is reached with the lowest UBZ value of 5.6% of the operating CEC.Overall interpretation drawn from the results according to UBZ shows that decreasing the particles size improves the performance of ion exchange process; as well as decreasing the fl ow rate.Nevertheless, the increase of L/D to a certain extent does not improve ion exchange performances.Keywords.Cationic Exchange Capacity,
Source: BASE
Institutions: Gembloux Agro-Bio Tech, University of Liège
Language: English
Subfield: Water Science and Technology
Field: Environmental Science
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2136583320