Performance analysis of a 7‐kW crystalline silicon generator after 17 years of operation in Madrid
Year: 2013
Type: article
Abstract: The degradation observed on a 7‐kWp Si‐x photovoltaic array after 17 years of exposure on the roof of the Solar Energy Institute of the Polytechnic University of Madrid is presented. The mean peak power degradation has been 9% over this time, or an equivalent to 0.53% per year, whereas peak power standard deviation has remained constant. The main visual defects are backsheet delamination at the polyester/polyvinyl fluoride outer interface and cracks in the terminal boxes and at the joint between the frame and the laminate. Insulation resistance complies well with the requirements of the International Electrotechnical Commission 61215 tests. Copyright © 2013 John Wiley & Sons, Ltd.
DOI: 10.1002/pip.2379
Authors: Eduardo Lorenzo, Roberto Zilles, Rodrigo Moretón, Trinidad Gómez, Ainhoa Martínez de Olcoz
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2139449538