Work

Ein Methodenkonzept zur Parametrisierung der Perfusionshomogenität : Therapiekontrolle der altersabhängigen Makuladegeneration

Year: 2010
Type: dissertation
Abstract: The presented dissertation describes the development of a clinically applicable angiographic technique allowing to analyze the choroideal microcirculation in severely impaired patients afflicted with age related macular degeneration; it was developed in order to objectively document success or failure of recently proposed therapeutic strategies. In its principle, the technique applies the well known principle of dye dilution analysis, here using indocyanin green, a long corroborated indicator inducing fluorescence so that it can be applied in patients with strongly developed pigment epithelium. For a number of reasons, the obtained video-films and the derived perfusograms are difficult to analyze, mostly due to the simple reason that the patients cannot readily cooperate (due to their disease related difficulties to focus on the test-light in the angiograph). The pilot studies performed in patients were founded on extensive preparatory experiments, which had established that perfusographic displays could be calculated from between 70 and 130 film frames, the information of which was represented pixel by pixel in the local and thence general dynamics of indicator inflow and outflow. Under much simpler experimental condition, this routine had been developed and standardized in the Department of Physiology; the presented dissertation applies this competence to a functionally decisive region of the human retina, more specifically to the haemodynamic analysis of the underlying choroideal paracapillary bed (a sub-regions with an extension of about 30 pixel radii). The major part of the presented dissertation refers to the many anatomic, physiological and thence haemodynamic peculiarities of the human choroidea (which in normal subjects is the site of luxury perfusion); the resulting "anormalities" follow from clearly comprehensible topological reasons (large overall cross sectional area) and arterial input. As a result, the perfusion dynamics - here contrasting all other known applications of dye-dilution curves in intact circulations is not complicated by so called "recirculation" stemming from the dye circulating on functional shunts between the venous and arterial segments of the circulatory system. On the one hand, this made it possible to to limit the transfer analysis to comparatively simple inflow-outflow dynamic, on the other hand, however, an unavoidable drawback became obvious, namely extremely retarded venous outflow in comparison to the previously established "gold standard" in conventional retinal angiography. We succeeded in describing 3/4 of the information of the black-and-white film in a single false-color-image describing the complete inflow-kinetics. Thus the physicians are enabled to evaluate a single color-pattern in each case, which is much simpler as the comparison of films. Having learned about only biphasic transfer functions, it became possible to avoid its direct mathematical modelling; instead, the much more readily analyzable inverse functions could be used to smoothen the deficient films (for the compensation of unavoidable eye movements) and to interpolate the erroneous film sequences (due to deficits in the refracting media), i.e. to improve the signal to noise ratio of unavoidably deficient films. These subroutines made it possible to use 8 out of 9 of the incompletely documented perfusion experiments in perfusograms. In conclusion, the mathematical routines and the applied background information allowed the offline reconstruction of considerably improved black-and-white films by minimizing the unavoidably occurring deficits; these surrogate films allow the inspection of the angiograms by physicians, who are not familiar with the technical complexities, but who are used to analyze other types of dynamic video-films (for example in their attempt to compare the results of therapeutic interventions).
Language: German
Field: Medicine
Open Access status: green
OpenAlex ID: W213966110
Cites: 15
Cited by:
Related to: 10