Work

Compensating for torsion windup in steerable needles

Year: 2008
Type: conference-paper
Abstract: Long, flexible, bevel-tip needles curve during insertion into tissue, and rotations of the needle base reorient the tip to steer subsequent insertions. Friction between the tissue and the needle shaft, however, can cause a severe discrepancy between the needle base and tip angles. In this paper, I demonstrate an algorithm to properly align the entire length of the needle using torque measured at the base. My algorithm uses several intermediate base rotations to align the orientation of points along the shaft with the desired angle, with minimal remaining torque exerted by the base. I performed an experimental validation with four angle sensors attached to the needle throughout the tissue. My compensation algorithm decreased the lag throughout the needle by up to 88%.
Author: Kyle B. Reed
Language: English
Open Access status: green
OpenAlex ID: W2146175757
FWCI: 6.524
Cites: 14
Cited by: 17
Related to: 10