Evaluation of the Leukocyte Esterase and Nitrite Urine Dipstick Screening Tests for Detection of Bacteriuria in Women with Suspected Uncomplicated Urinary Tract Infections
Year: 1999
Type: article
Study design: Observational Study
Abstract: A positive dipstick urinalysis (i.e., leukocyte esterase test and/or nitrite test) did not reliably detect significant bacteriuria in 479 ambulatory women with suspected uncomplicated urinary tract infection; 18.9% of the urine samples that demonstrated significant bacteriuria would have been rejected by the laboratory based on a negative urinalysis screen.
Source: Journal of Clinical Microbiology
Authors: Heather Semeniuk, Deirdre Church
Institutions: Calgary Laboratory Services, University of Calgary
Language: English
Subfield: Urology
Field: Medicine
Domain: Health Sciences
Open Access status: bronze