Year: 2006
Type: article
Abstract: Effects of variations in time period and voltage level were examined during the cyclic corrosion of polymer electrolyte membrane (PEM) fuel cell catalyst. Decay rates in the electrochemical area were found to increase when voltage waves, square or triangular, were cycled at a shorter period, and when the lower voltage level was set below the platinum oxide reduction peak ( vs reversible hydrogen electrode). Cell performance losses were compared to the Tafel prediction. The double layer current densities and approximate electrode wettabilities were found to increase upon cycling.
DOI: 10.1149/1.2400204
Authors: C. H. Paik, G. S. Saloka, G. W. Graham
Institution: Ford Motor Company (United States)
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
Funder: Ford Motor Company
OpenAlex ID: W2160755908