Device-Associated Infections among Neonatal Intensive Care Unit Patients: Incidence and Associated Pathogens Reported to the National Healthcare Safety Network, 2006–2008
Year: 2012
Type: article
Study design: Observational Study
Abstract: OBJECTIVE: To describe rates and pathogen distribution of device-associated infections (DAIs) in neonatal intensive care unit (NICU) patients and compare differences in infection rates by hospital type (children's vs general hospitals). PATIENTS AND SETTING: Neonates in NICUs participating in the National Healthcare Safety Network from 2006 through 2008. METHODS: We analyzed central line-associated bloodstream infections (CLABSIs), umbilical catheter-associated bloodstream infections (UCABs), and ventilator-associated pneumonia (VAP) among 304 NICUs. Differences in pooled mean incidence rates were examined using Poisson regression; nonparametric tests for comparing medians and rate distributions were used. RESULTS: Pooled mean incidence rates by birth weight category (750 g or less, 751-1,000 g, 1,001-1,500 g, 1,501-2,500 g, and more than 2,500 g, respectively) were 3.94, 3.09, 2.25, 1.90, and 1.60 for CLABSI; 4.52, 2.77, 1.70, 0.91, and 0.92 for UCAB; and 2.36, 2.08, 1.28, 0.86, and 0.72 for VAP. When rates of infection between hospital types were compared, only pooled mean VAP rates were significantly lower in children's hospitals than in general hospitals among neonates weighing 1,000 g or less; no significant differences in medians or rate distributions were noted. Pathogen frequencies were coagulase-negative staphylococci (28%), Staphylococcus aureus (19%), and Candida species (13%) for bloodstream infections and Pseudomonas species (16%), S. aureus (15%), and Klebsiella species (14%) for VAP. Of 673 S. aureus isolates with susceptibility results, 33% were methicillin resistant. CONCLUSIONS: Neonates weighing 750 g or less had the highest DAI incidence. With the exception of VAP, pooled mean NICU incidence rates did not differ between children's and general hospitals. Pathogens associated with these infections can pose treatment challenges; continued efforts at prevention need to be applied to all NICU settings.
DOI: 10.1086/668425
Language: English
Field: Medicine
Domain: Health Sciences
Keywords: device-related infection, neonatal intensive care, central line-associated bloodstream infection, ventilator-associated pneumonia, infection incidence, pathogen distribution, methicillin-resistant Staphylococcus aureus, coagulase-negative staphylococci, Candida, Pseudomonas, Klebsiella, birth weight, children's hospitals
Open Access status: green
Funder: National Institutes of Health
Award: G7543494365
OpenAlex ID: W2163075042