Year: 2011
Type: conference-paper
Abstract: Surface potential decay measurement is a simple and low cost tool to examine electrical properties of insulation materials. During corona charging stage, needle-grid electrodes system is often used to achieve uniform charge distribution on the surface of the sample. However, there is little report on the effects of geometrical parameters and voltage values of the charging system on the surface potential and its characteristics. In the present report simulations based on gas discharging physics similar to [1] have been carried out to investigate dynamic surface charge formation. The geometry of in the model includes a 174?m radius of curvature needle setting perpendicular to a 0.5mm thickness grid electrode and a 27.5mm diameter with 50?m thickness polyethylene. The bottom surface of the polyethylene is grounded and it is 3cm and 1.5cm away from the needle electrode and grid electrode respectively. The simulations were initially performed under the following conditions: the needle electrode was set as -8000V and the grid electrode -2000V. It has been found that an impulse current appeared after 0.3?s charging which represented the corona effect. The effect of adding a grid electrode can be clearly seen from the logarithmic plot of electrons. Finally, surface charge density on the sample has been obtained.
Authors: Yuan Zhuang, G Chen, Mihai Rotaru
Institution: University of Southampton
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W21726580