Abstract: A microbial biosensor system was developed for nitrate monitoring. The system was constructed with an immobilized microorganism (Paracoccus dinitrificans IAM 12479), a Clark-type oxygen electrode, a micro-tube pump, and a recorder. The method was based on the determination of the oxygen consumption by the microorganism with the electrode in presence of nitrate. Optimum conditions for the sensor system was established as follows; concen- tration of immobilized cells on the membrane: 10 8 cells/cm 2 , pH: 7.0, temperature: 30°C, flow rate: 1.2 ml/min, glu- cose concentration: 0.1 g/l. One assay was completed within 15 min and a calibration curve was linear in the range of 5 - 50 mg/l. This system was applied to the nitrate monitoring during fish feeding. The nitrate concentrations determined by the sensor were closely related to those by the conventional method.