Year: 2007
Type: article
Abstract: We read with great interest the study by Traore and coauthors, comparing an alcohol hand gel with a liquid hand hygiene formulation in an intensive care unit [1]. The authors reported better user acceptability for the gel. Compliance for both formulations was significantly better (P = 0.035) when healthcare workers had easy access to hand rubs, but the difference in compliance between the gel and the liquid was not statistically significant. We are concerned that readers may conclude that gels are points out that the gel performed significantly better on skin tolerance parameters. Easy access, however, was the only significant predictor for compliance. The article also mentions ‘superior acceptance ’ of the gel, but acceptability scores of 39.1 and 40 (P = 0.44) were presented. Surprisingly, compliance
Source: Critical Care
DOI: 10.1186/cc5947
Authors: Matthias Maiwald, Andreas F Widmer
Institutions: Flinders Medical Centre, University Hospital of Basel
Language: English
Subfield: Infectious Diseases
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $4,190
OpenAlex ID: W2083261384