Technique Development of Cleaning Validation for Chlordiazepoxide Ip Tablets Dosage Form by
Year: 2013
Type: article
Abstract: Carefully designed cleaning validation and its evaluation can ensure that residues of activenbsp;pharmaceutical ingredient will not carry over and cross-contaminate the subsequent product.nbsp;Chemical inspection method was developed and validated for the verification and determination ofnbsp;chlordiazepoxide in the production area and to confirm the efficiency of the cleaning procedure asnbsp;per CGMP regulations. First all equipments, used in the production of chlordiazepoxide, werenbsp;visually inspected for the cleanliness and were found visually clean. nbsp;Chemical inspection was donenbsp;on basis of 10 ppm criteria. Range of chemical residue was 1.48-9.89 ppm in dispensing booth, 0.319.28 ppm in granulation room, 0.00 to 9.94 in sifter, 0.00 to 4.03 in sifter cum multimill, 0.00 to 7.01nbsp;in rapid mixer granulator, 2.48 to 8.06 in fluidized bed dryer, 0.00 to 8.01 in conta blender, 0.00 tonbsp;9.44 in compression cubicle and compression machine, 0.00 to 3.01 in coating room and coatingnbsp;machine and 0.00 to 9.85 in blister packing room and blister packing machine. Result indicated thatnbsp;calculated limit of chemical residue was not exceeded over prescribed limit during three consecutivenbsp;batches of production after cleaning procedure. Hence, it can be said that this cleaning methodnbsp;validation on solid dosage forms of chlordiazepoxide can be used in routine cleaning to avoid thenbsp;risk of cross contamination.
DOI: 10.69580/przkj643
Language: English
Subfield: Analytical Chemistry
Field: Chemistry
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2185340397