Determination of serum and urinary urate with reusable uricase strip
Year: 2004
Type: article
Abstract: Commercial uricase has been immobilized covalently onto alkylamine glass beads affixed on a plastic strip with a conjugation yield of 87mg/g and 11.5% retention of initial activity of free enzyme. Maximum activity of immobilized enzyme was attained at pH 8.8, when incubated at 40°C for 20 min. K m for uric acid and V m a x of immobilized enzyme were 0.15mM and 0.68μmoles H 2 O 2 /min respectively. A method for uric acid determination in serum and urine was developed using the strip bound enzyme. The method is based on the measurement of H 2 O 2 generated from uric acid by using a colour reaction consisting of 4-aminophenazone, p-hydroxybenzoic acid and horseradish peroxidase as chromogenic system. The minimum detection limit of the method was 1.68mg/dl and recovery of added uric acid in urine was 90%.The coefficient of variation (CV) were <5 and <2% for within batch and between batch respectively. The immobilized enzyme lost 50% of its initial activity after its regular uses for over 3 weeks, when stored in 0.05M glycine NaOH buffer, pH 8.8 at 4°C.
Authors: Sushma Sushma, Rekha, Vijay Kumar, Suman Rani, C.S. Pundir
Language: English
Subfield: Molecular Biology
Domain: Life Sciences
Open Access status: diamond
OpenAlex ID: W2185405698