Year: 2009
Type: dissertation
Abstract: Sleep apnea is defined as a repetitive cessation of airflow in spite of breathing efforts. In the middle-aged population, the prevalence of sleep apnea is 9 – 24%. Sleep apnea increases significantly the risk of cardiovascular disease, stroke, high blood pressure, diabetes and accidents. For example, untreated severe sleep apnea was found to increase fatal cardiovascular events by more than 500% in a 12 year follow-up. Traditionally, overnight polysomnography has been the primary method for diagnosing the disease and only recently have portable devices been accepted as alternative tools for diagnostics of sleep apnea. The aim of the first study of this work was to design, construct and evaluate a portable device (Venla) suitable for recording of sleep apnea. In the second study, the clinical potential of a successor (APV2) of the device developed in the first study was evaluated. The device dependence of the reliability of an automatic analysis of sleep apnea events was investigated in the third study. In the fourth study, a portable device (Emma) was developed for monitoring of the level of consciousness in the intensive care unit (ICU); this device is based on recording of auditory evoked potentials. Technical and clinical evaluation of the novel portable monitoring devices (Venla and APV2) revealed that they possessed similar diagnostic capabilities as a reference laboratory instrument (Embla) in detecting sleep apnea. No statistical differences were found in the apnea hypopnea index (AHI) or oxygen desaturation index (ODI) recorded with Venla and APV2 when compared to those recorded with the reference laboratory instrument. Furthermore, the AHI and ODI values determined with the novel devices and the reference instrument were highly correlated. Importantly, the novel devices showed better technical reliability, with fewer failed recordings (Venla 6.7% and APV2 4.0%) than the widely used commercial device (Embletta, 19.2%). The results of the third study indicate that an exclusion of obstructive sleep apnea (OSA) should never be done based on automated analysis alone. The diagnosis of mild OSA should always be based on manual analysis of the recording, but if the result of the automatic analysis is detection of moderate or severe sleep apnea, it may be accepted without further manual confirmation of the validity of the analysis. Importantly, classifying the disease further into the obstructive, mixed or central types should always be done manually. In the fourth study a compact portable battery operated device for measuring event-related potentials, somatosensory evoked potentials, as well as the electroencephalogram and electrocardiogram was designed, constructed and programmed for off-line monitoring of the level of consciousness or depth of sedation. The device is intended to be used in intensive care units and emergency rooms, which places special requirements on the robustness and simplicity of the use of the instrumentation. Technical evaluation and in vivo recordings revealed that the device can be reliably and safely used for clinical diagnostics. National Library of Medicine Classification: QT 36, WB 142, WF 143, WM 188, WL 341, WL 705 Medical Subject Headings: Sleep Disorders/diagnosis; Sleep Apnea Syndromes/diagnosis; Sleep Apnea, Obstructive/diagnosis; Consciousness; Consciousness Disorders; Monitoring, Ambulatory/instrumentation; Polysomnography; Evoked Potentials, Auditory; Electroencephalography; Intensive Care Units; Equipment Design; Biomedical Engineering To my family: Leena, Timo and Tiina
Author: Pekka Tiihonen
Language: English
Subfield: Physiology (medical)
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2186521440