Work

First operation of the LANL/AES normal conducting radio frequency photoinjector

Year: 2011
Type: article
Abstract: The LANLI AES normal-conducting radio-frequency (NCRF) injector has undergone high power testing, conftrming field gradients of up to 10 MY 1m at the cathode.Most NCRF designs are limited to low-dutyfactor operation to constrain rf power consumption and limit ohmic heat generation.This cavity structure utilizes high density micro-channel cooling to successfully remove heat with the option of dynamic temperature control to actively adjust cavity resonance.This first high power rf test demonstrated stable cw (100% duty cycle) operation using resonant frequency tracking and produced intentional dark current emission from a roughened cathode blank.Resulting end-point x-ray measurements conftrm the cathode gradient of 9.8 ± 0.2 MV/m required for acceleration of nC bunches to a beam energy of 2.5 MeV.
Language: English
Open Access status: green
OpenAlex ID: W2187636740
FWCI:
Cites: 2
Cited by:
Related to: 10