Work

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure.

Year: 2014
Type: article
Study design: Case Report
Abstract: Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, including emphasis on pre and intra operative echocardiographic diagnosis and treatment.
Source: PubMed
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W219309600
FWCI: 0.441
Cites: 10
Cited by: 2
Related to: 10