Effects of Stride Rate Manipulation in Shoes with Different Drop Heights
Year: 2014
Type: conference-paper
Abstract: Runners who land with a more dorsiflexed ankle (i.e., an increased angle of the foot relative to the ground) at heel-strike may be at an increased risk for injury. PURPOSE: To determine whether rearfoot strike runners can reduce foot angle at contact without increasing metabolic cost, heart rate, tibial acceleration, or perceived exertion while running by using a lower drop height shoe. METHODS: Twelve healthy recreational runners (20.8±1.2 yrs, 64.2±7.3 kg) with a mean VO2 max 47.9 (8.3) ml*kg-1*min-1 and who regularly ran with a rearfoot strike pattern were recruited and provided informed consent prior to participation. Tibial acceleration, foot angle, VO2, HR, and RPE, were recorded when the participant reached steady state during treadmill running at a constant speed at preferred step frequency (PSF), PSF+7.5% and PSF+15% in two shoes; Asics Gel-Flux (13 mm drop height and 11.7 mm, for men and women, respectively) and Gel-Lyte (5.4 mm drop height and 4 mm, for men and women, respectively). RESULTS: VO2 and RPE were not significantly different between shoes and among stride frequency conditions. Foot angles were lower in the Gel-Lyte (p=0.005) and during the +15% PSF condition compared to +0% and +7.5% PSF (p=0.005 & p=0.01, respectively). HR was significantly higher in the +15% PSF condition than in the +7.5% PSF condition (p=0.048), and was not significantly different between the two drop height conditions (p=0.327). Tibial acceleration was significantly higher in the lower drop height condition when compared to the higher drop height condition (p=0.04), and was significantly higher at +7.5% PSF when compared to +15% PSF (p=0.01). CONCLUSION: Running in a lower drop height shoe can decrease foot angles at contact, as can increasing the stride frequency by +15%. Such changes may help diminish injury risk with no increased metabolic cost or perceived physical exertion. Table 1 – Mean (SD) for tibial acceleration (TA; g’s), foot angle (FA; degrees), VO2 (ml*kg-1*min-1), HR (bpm) and RPE for each shoe and step frequency condition. Asics Gel-Lyte Asics Gel-Flux PSF +0% +7.50% +15% PSF +0% +7.50% +15% VO2 29.8±0.2 30.0±3.4 29.7±2.8 29.8±2.9 29.9±0.2 29.9±3.4 29.8±3.6 30.1±3.6 RPE 8.4±0.3 8.1±1.4 8.5±1.2 8.7±1.3 9.1±0.4 9.1±2.2 8.7±1.8 9.4±2.0 FA 12.4±1.7 13.9±4.8 12.7±5.2 10.5±4.0 14.3±0.5 15.0±4.2 14.3±5.1 13.7±4.9 TA 3.4±0.9 3.5±1.1 3.4±0.9 3.2±0.9 2.7±0.5 2.8±0.6 2.7±0.6 2.6±0.4 HR 148.0±12.0 148.4±12.0 146.4±13.0 149.1±11.0 150.3±10.0 150.4±9.9 147.8±10.1 152.7±10.1
Authors: Emily J Ammon, Kyle D. Allen, J. C. Smith, Scott P McLean
Institution: Southwestern University
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W21985036