Determination of ion temperature with single and triple Langmuir probes
Year: 1994
Type: article
Abstract: This work discusses a method of determining plasma Ion Temperature using a single and a triple Langmuir probe in a plasma system having a finite ion temperature.The triple probe measures the plasma potential difference between a pair of the floating probes and ion saturation current, Ji , from another pair.The single probe is biased at a positive voltage higher than the space potential ( corresponding to the bend in the I-V characteristic curve ) where the electron current approaches a saturation value.It measures the electron saturation current, Je .The electron temperature, T, , is determined by the plasma potential difference from the triple probe.However, instead of determining the electron density, ne , from the relation Ji = exp (-1/2)en, /k Te/mi and T by neglecting Ti , it is now obtained from J, .It is not needed to make the zero ion temperature assumption which is no longer valid when the ion temperature is finite or higher than the electron temperature.Taking ne and Te , the ion temperature can now be calculated from the relationship Ti = (m 2 /k)(Ji exp (1/2)/ene) 2 -T,.
Authors: T.F. Yang, P. Liu, Q.X. Zu
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2225530698