Year: 2010
Type: article
Abstract: Slender concrete walls incorporated into tilt-up constructionover the past 60 years have performed remarkably well underout-of-plane wind and seismic loads. While issues associatedwith seismic wall anchorage gave this form of construction ablack-eye in the early days, the concrete walls themselveshave always performed very well even as far back as theirfirst use in the early 1900s. Yet the height-to-thicknesslimitations in 1985 and earlier model building codes wereproved irrational and were removed. We as engineers expectbuilding codes to evolve and advance the state of the art witheach successive edition. The latest edition of ACI 318-08 hassignificantly revised the slender walls design procedures, yetnot necessarily advancing the state of the art. The latest ACI318 edition is largely revising slender wall design back tomatch equations found in the old 1997 UBC.This paper revisits the historical effort SEAOSC played in thedevelopment of the original slender wall provisions in the late1970s, and why ACI is now revising their slender wall designprovisions to agree with concepts developed over 30 yearsago by SEAOSC. While these original concepts were basedon empirical data from full-scale tests conducted in the early1980s, only within the last five years have we really begun tofully understand the behavior of these thin concrete memberswhen subjected to combined axial load and large horizontalforces.
Authors: John Lawson, James S. Lai
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W22378743