Direct comparison of a Ca^+ single-ion clock against a Sr lattice clock to verify the absolute frequency measurement
Year: 2012
Type: article
Abstract: Optical frequency comparison of the (40)Ca(+) clock transition ν(Ca)((2)S(1/2-)(2D(5/2), 729 nm) against the (87)Sr optical lattice clock transition ν(Sr) ((1)S(0)-(3)P(0), 698 nm) has resulted in a frequency ratio ν(Ca) / ν(Sr) = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν(Ca) / ν(Sr) to reach 1 × 10(-15) in 1000s and yielded a value consistent with that calculated from separate absolute frequency measurements of ν(Ca) using the International Atomic Time (TAI) link. The total uncertainty of the frequency ratio using optical comparison (free from microwave link uncertainties) is smaller than that obtained using absolute frequency measurement, demonstrating the advantage of optical frequency evaluation. We note that the absolute frequency of (40)Ca(+) we measure deviates from other published values by more than three times our measurement uncertainty.
Source: Optics Express
DOI: 10.1364/oe.20.022034
Authors: Kensuke Matsubara, Hidekazu Hachisu, Ying Li, Shigeo Nagano, Clayton Locke, Asahiko Nogami, Masatoshi Kajita, Kazuhiro Hayasaka, Tetsuya Ido, Mizuhiko Hosokawa
Language: English
Subfield: Atomic and Molecular Physics, and Optics
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,270
OpenAlex ID: W2238361384