Measuring oxygen transfer efficiency (OTE) at the Eindhoven WWTP using real-time off-gas analysis in circular aeration tank
Year: 2011
Type: conference-paper
Abstract: Aeration efficiency in the activated sludge basin of the Eindhoven wastewater treatment plant was monitored during two off-gas measurement campaigns using the ASCE method for oxygen transfer testing. Different locations were sampled and revealed differences in αSOTE values both in tangential as in radial direction. The highest values were found at the end of the aeration zone (ca.38%), the lowest at the start (ca.30%) and intermediate values in between. Differences in the radial direction were negligible at the start of the aeration zone, but became more significant towards the end. This hints that homogeneity in terms of OTE can be assumed at the start of the aeration zone, but does not longer hold at the end of the aeration zone.
Institution: Ghent University
Language: English
Subfield: Pollution
Field: Environmental Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2247284835