Accuracy of Newer-Generation Home Blood Glucose Meters in a Diabetes Research in Children Network (DirecNet) Inpatient Exercise Study
Year: 2005
Type: article
Abstract: BACKGROUND: The objective of this study was to assess how the accuracy of the FreeStyle Flash (Abbott Diabetes Care, Alameda, CA) meter compares with that of the One Touch Ultra (Lifescan, Milpitas, CA) home glucose meter (HGM). RESEARCH DESIGN AND METHODS: Fifty children with type 1 diabetes (T1D), 10-17 years old, were admitted for two separate 24-h periods to assess the effect of exercise on subsequent nocturnal hypoglycemia. Resulting data were used in a preplanned analysis of the accuracy of the Ultra and FreeStyle HGMs. Glucose levels were measured throughout the day and night and every 15-20 min during a standardized exercise protocol. Reference samples were assayed in a central laboratory using a hexokinase enzymatic method. These reference glucose measurements were paired with HGM values from venous blood obtained within +/- 5 min. RESULTS: The median relative absolute difference was 5% for both the Ultra and FreeStyle HGMs, and the percentages of pairs meeting the International Organisation for Standardization criteria were 99% and 98%, respectively. The FreeStyle tended to read slightly higher than the reference method (median difference = +3 mg/dL; P < 0.001), and there was trend in this direction for the Ultra (median difference = +2 mg/dL, P = 0.15). Sensitivities for detection of hypoglycemia (reference < or = 60 and HGM < or = 70 mg/dL) were 96% and 100% for the Ultra and FreeStyle, respectively, and corresponding false-positive rates were both 5%. CONCLUSIONS: In a controlled clinical setting using venous blood samples, both the Ultra and FreeStyle meters demonstrated a high degree of accuracy compared with the laboratory reference over a broad range of glucose concentrations in children with T1D.
Author: The Diabetes Research in Children Network (Direcnet) Study Group
Institution: Jaeb Center for Health Research
Language: English
Subfield: Endocrinology, Diabetes and Metabolism
Field: Medicine
Domain: Health Sciences
Open Access status: green
Awards: General Clinical Research Center, Glucose Sensors in Children with Type I Diabetes, Coordinating Center for Studies of Glucose Sensors in T*, GENERAL CLINICAL RESEARCH CENTER, General Clinical Research Center, Prevention of Nocturnal Hypoglycemia: Effect on Neurologic Outcome in Toddlers, G2678868255, Hypoglycemia in Children and Adolescents with T1DM: Mechanisms and Prevention, General Clinical Research Center, Cooperative Multicenter Diabetes Research Network for Hypoglycemia Prevention, Prevention of Hypoglycemia and Associated Complications in Type 1 Diabetes, General Clinical Research Center, Yale Study of Closed-Loop Automated Glucose Control for Hypoglycemia Prevention
OpenAlex ID: W2253753776
