Two-phase pressure drop of refrigerants during flow boiling in small channels : an experimental investigation and correlation development.
Year: 1999
Type: conference-paper
Abstract: Two-phase flow pressure drop measurements were made during a phase-change heat transfer process with three refrigerants (R-134a, R-12, and R-113) at six different pressures ranging from 138 kPa to 856 kPa, and in two sizes of round tubes (2.46 mm and 2.92 mm inside diameters) and one rectangular channel (4.06 x 1.7 mm). State-of-the-art large-tube correlations failed to satisfactorily predict the experimental data. The data were used to develop a new correlation for two-phase pressure drop during flow boiling in small channels. The correlation was then tested against the experimental data for the three refrigerants; the error was {+-}20%.
Authors: M.-C. Chyu, Thanh‐Nhan Tran, M.W. Wambsganss
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2261473878