Abstract: This paper describes LOFT Tests L2-2, L2-3, and L3-0 and presents conclusions reached from analysis of these tests. The LOFT L2 series of tests, called the power ascension series, originally consisted of six tests. The first four tests, L2-1 through L2-4, were identical except for step-wise increases in core power for each test. Comparison of these tests, and the nonnuclear Test L1-5, was planned to evaluate the effect of core power on system and ECC behavior during large cold leg break LOCA's. Tests L2-5 and L2-6 were to provide parametric investigations of the effect of loss of offsite power and prepressurized fuel. Prior to the start of the L2 series, it was decided Test L2-1 was not necessary due to the information learned from the LOFT nonnuclear tests and PBF lead rod tests. Tests L2-2 and L2-3 are described. The posttest analysis of Tests L2-2 and L2-3 is discussed, and conclusions reached from the comparisons of the experimental data to computer calculations presented. In addition, the results and implications of computer calculations on a commercial size PWR with the same model used for LOFT are presented. Finally, Test L3-0 is described and conclusions reached from it introduced.