Work

Low-frequency Noise Absorption by a Shunt- Ed Loudspeaker

Year: 2013
Type: conference-paper
Abstract: Low-frequency noise is annoying and hard to deal with.By connecting certain shunt circuit to a moving-coil loudspeaker, we demonstrate improved low-frequency absorption of normal incident sound.The loudspeaker is installed in a cavity of 5cm in depth.Negative impedance converter is used to construct a hybrid RLC-parallel and RLC-series shunt circuit.The lowfrequency reactance of the shunted loudspeaker system is reduced in magnitude together with a modified system damping.The proposed device is measured in a well calibrated impedance tube, and good noise absorption performance is achieved in the frequency range of 100Hz to 400Hz as predicted.
Language: English
Open Access status: green
OpenAlex ID: W2282012504
FWCI:
Cites: 16
Cited by: 1
Related to: 10