Low-level 226Ra determination in groundwater by SF-ICP-MS: optimization of separation and pre-concentration methods
Year: 2015
Type: article
Abstract: Background Inductively coupled plasma mass spectrometry (ICP-MS) techniques have been widely used for analysis of long-lived environmental radionuclides. In this paper, we present an optimization of the sector field (SF)-ICP-MS technique for the analysis of 226Ra in groundwater samples using a method of pre-concentration of radium in water samples. Methods The separation protocol and a sequential application of ion exchange and extraction chromatography have been optimized, and related polyatomic interferences and matrix effects affecting the 226Ra signal were investigated. Results Analyzing 12 replicates (water spiking at 22 fg g−1 of 226Ra), the 226Ra recovery efficiency close to 100 % has been obtained. The instrumental 226Ra detection limit of 0.09 fg g−1 (3σ criterion) and the absolute detection limit of 0.05 fg in a 25-mL groundwater sample have been reached. Conclusions An optimization of the radium separation method and a pre-concentration of radium in groundwater samples led to high radium recoveries, almost up to 100 %. The same could be said with respect to the separation of the interfering elements, important for the quantitative 226Ra analysis by SF-ICP-MS. The improvements in the separation and pre-concentration techniques also helped to improve the 226Ra detection limit down to 0.05 fg/25 mL of groundwater sample.
Language: English
Subfield: Radiation
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,390
Funder: Nuclear Physics
OpenAlex ID: W1855872495