Abstract: This paper is concerned with the ultimate failure of composite floor slabs in an extreme loading condition such as a fire. The tolerance for high deformations becomes unimportant in these situations and so alternative load paths can be established and mobilised, thereby facilitating secondary load carrying mechanisms after the conventional strength limits have been reached. These secondary mechanisms are largely related to membrane forces developing in the slabs. There is a need to establish the appropriate failure criteria of floor slabs based on a fundamental assessment of behaviour rather than from an empirical or semi-empirical approach. This study focuses on the failure state associated with rupture of the reinforcement in slab strips, which become lightly reinforced due to the early loss of the steel deck and unprotected beams. In this context, quantitative solutions have been proposed by researchers at Imperial College for isolated slab strips at both ambient and elevated temperatures [1,2]; these have been further developed to accommodate full floor slabs in the same conditions [3]. An experimental investigation has been completed at ambient temperature to validate the proposed analytical model for slab strips and the findings will be discussed herein. The experimental program also includes tests on full slabs, and these will be reported on at a later stage.
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2294585341