Size Exclusion Chromatography as a Tool for Natural Organic Matter Characterisation in Drinking Water Treatment
Year: 2008
Type: dissertation
Abstract: Natural organic matter (NOM), ubiquitous in natural water sources, is generated by biogeochemical processes in both the water body and in the surrounding watershed, as well as from the contribution of organic compounds that enter the water as a result of human activity. NOM significantly affects the properties of the water source, including the ability to transport metals, influence the aggregation kinetics of colloidal particles, serve as a food source for microorganisms and act as a precursor in the formation of disinfection by-products (DBPs), as well as imparting a brown colour to the water. The reactivity of NOM is closely tied to its physicochemical properties, such as aromaticity, elemental composition, functional group content and molecular weight (MW) distribution. The MW distribution is an important consideration from a water treatment perspective for several reasons. For example, low MW NOM decreases the efficiency of treatment with activated carbon, and this fraction is thought to be the portion most difficult to remove using coagulation. The efficiency of membranes in the treatment of drinking water is also influenced by the MW distribution of NOM, while some studies have shown that the low MW fraction contributes disproportionately to the formation of bioavailable organic matter, therefore promoting the formation of biofilms in the distribution system. For these reasons, understanding the MW distribution of NOM is important for the treatment of natural waters for use as drinking waters. Optimisation of a high pressure size exclusion chromatography (HPSEC) method for analysis of the MW distribution of NOM in natural waters is described (Chapter 2). Several parameters influencing the performance of HPSEC are tested and an optimised set of conditions illustrated.These parameters included eluent composition, ionic strength of the sample, flow rate and injection volume. Firstly, it was found that increasing the ionic strength of the HPSEC eluent resulted in less exclusion of NOM from the stationary phase. Stationary phases used in HPSEC contain a residual negative charge that can repel the negatively charged regions of NOM, effectively reducing the accessible pore volume. By increasing the ionic strength, interactions between the stationary phase and eluent enabled a larger effective pore size for the NOM analytes. However, increasing ionic strength of the eluent also resulted in a loss of peak resolution for the NOM portion able to access the pore volume of the stationary phase. Determining the ideal eluent composition required the balancing of these two outcomes. Matching of the ionic strength of the sample with the eluent was also an important consideration. Retention times were slightly lower when the sample ionic strength was not matched with the eluent, especially for the lowest MW material, although the effect on chromatography was minimal. Flow rate had no effect on the resolution of the HPSEC chromatogram for the portion of material able to permeate the pore space of the stationary phase. Changes in the volume of sample injected had a marked effect on the elution profile of the NOM sample. Besides the obvious limitation of detection limit, only minor changes in elution profile were obtained up to an injection volume of 100 µL. Volumes above this value, however, resulted in significant peak broadening issues, as well as an undesirable effect on the low MW portion of detected DOC.In Chapter 3, high pressure size exclusion chromatography with UV254 [subscript] and on-line detection of organic carbon (HPSEC-UV254[subscript]-OCD) was used to compare the removal of different apparent MW fractions of DOC by two process streams operating in parallel at the local Wanneroo groundwater treatment plant (GWTP). One of these two process streams included alum coagulation (operating in an enhanced coagulation mode (EC) for increased DOC removal) and the other stream included a magnetic ion exchange (MIEX®) process followed by alum coagulation (MIEX®-C). The MIEX® process is based on a micro-sized, macroporous, strong base anion exchange resin with magnetic properties, which has been designed to remove NOM through ion exchange of the anionic sites in NOM. Water was sampled from five key locations within these process streams, and the DOC at each location was characterised in terms of its MW distribution. HPSEC was carried out using three different on-line detector systems, namely OCD, UV absorbance detection at 254 nm, and fluorescence detection (λex[subscript]= 282 nm; λim[subscript] = 353 nm). This approach provided significant information on the chemical nature of the DOC in the various MW fractions. The MIEX®-C process was found to outperform the EC process: these two processes removed similar amounts of high and low MW DOC, but the MIEX®-C process showed greater removal of DOC from the intermediate MW fractions. The two coagulation processes (EC and coagulation following MIEX®) showed good removal of the fractions of highest MW, while the MIEX® process alone was found to remove DOC across all MW fractions.These results seem to indicate that anionic groups, particularly susceptible to removal with MIEX® treatment, are well distributed across all MW fractions of NOM. In agreement with previous studies, MIEX®-C outperformed EC in the overall removal of DOC (MIEX®-C removed 25 % more DOC than EC). However, 70% of the additional DOC removed by MIEX®-C was comprised of a surprisingly narrow range of medium-high MW fractions. The development of a novel online organic carbon detector (OCD) for use with HPSEC for determining the MW distribution of NOM is described in Chapter 4. With UV absorbance detection, the magnitude of the signal is based on the extinction coefficient of the chromophores in the analytes being investigated; whereas the signal from an OCD is proportional to the actual organic carbon concentrations, providing significantly more information. The development of an online OCD involved the separation of analytes using HPSEC, removal of inorganic carbon species which may interfere with organic carbon determination, oxidation of the organic carbon to carbon dioxide, separation of the produced carbon dioxide from the aqueous phase and subsequent detection of the gaseous carbon dioxide. In the new instrument, following separation of components by HPSEC, the sample stream was acidified with orthophosphoric acid to a concentration of 20 mmol L-1[superscript], resulting in a pH of ≤ 2, in order to convert inorganic carbon to carbon dioxide. This acid dose was found to remove greater than 99 % of inorganic carbon once the acidified sample was passed through a hydrophobic polytetrafluoroethylene (PTFE) membrane allowing the passage of dissolved gases (under negative pressure from a vacuum pump) but restricting the flow of the mobile phase.Several factors influenced the oxidation of the organic carbon in the next step, including the dose of persulfate, the type and intensity of UV radiation and the composition of the capillary through which the sample stream passes. Through optimisation of this process, it was found that a persulfate dose of 0.84 mmol L-1[superscript] in the sample stream was required for optimum oxidation efficiency. A medium pressure UV lamp was compared to a vacuum UV lamp for its efficiency in oxidation of organic carbon to carbon dioxide. While the medium pressure lamp produced a far smaller percentage of its total radiation at the optimum wavelength for oxidation of organic compounds, the greater overall intensity of the medium pressure lamp was shown to be superior for this application. The composition of the capillary was shown to have a considerable effect on the oxidation efficiency. A quartz capillary, internal diameter 0.6 mm, was compared with a PTFE capillary, internal diameter 0.5 mm, for the oxidation of organic carbon by external UV treatment. While peak width, an important consideration in chromatographic resolution, was greater for the larger internal diameter quartz capillary, the lower UV transparency of PTFE combined with the shorter contact time, due to the reduced internal diameter of the capillary, resulted in a less efficient oxidation step using the PTFE capillary. The quartz capillary was therefore chosen for use in the UV/persulfate oxidation step for oxidation of organic carbon to carbon dioxide. Separation of the produced carbon dioxide from the sample stream was achieved by sparging with nitrogen and contacting the gas/liquid mixture with a hydrophobic PTFE membrane, restricting the passage of the liquid while allowing the nitrogen and carbon dioxide gases to pass to the detection system.The only factor influencing this separation was the flow of the nitrogen sparge gas, with a flow of 2 mL min-1[superscript] found to be optimum. Detection of produced carbon dioxide was via a Fourier transform infrared (FTIR) spectrometer with a Iightpipe accessory. The Iightpipe accessory was designed for use as a detector for gas chromatography and the small size of the detector cell was ideal for use with this application. Using the new system described, concentrations of a single peak could be determined with a detection limit of 31 ng and a determination limit of 68 ng. The development of the new OCD allowed characterisation of NOM in terms of its MW distribution and the UV and fluorescence spectral properties of each MW fraction. Further characterisation of MW fractions of NOM from a local groundwater bore was carried out by separation of the fractions by preparative HPSEC, followed by off-line analysis. Preparative HPSEC involved the injection of a pre-concentrated groundwater sample multiple times, using a large scale HPSEC column, then collecting and combining material of identical MW. This allowed each MW fraction of the sample to be further characterised as described in Chapter 5. Preparative HPSEC has only previously been applied to a small number of samples for t
Source: eSpace (Curtin University)
Author: Bradley Allpike
Language: English
Subfield: Health, Toxicology and Mutagenesis
Field: Environmental Science
Domain: Physical Sciences
Keywords: natural organic matter, molecular weight distribution, size exclusion chromatography, drinking water treatment, peak resolution, activated carbon adsorption, membrane fouling, disinfection by-products, biofilm formation, drinking water sources, coagulation, peak deconvolution, drinking water regulation
Open Access status: green
Funder: Curtin University of Technology
OpenAlex ID: W2299990313