Year: 1996
Type: article
Abstract: The present work considers the physiological responses of a fire fighter to work in a hot humid environment, by discussing work rate, ambient condi~ons, protective clothing, heart mte, oxygen uptake, and temperature regulation.A fire Eghter is subject to severe physiological stress during fire suppression activity, due to the combined effect of dagerous temperature extremes and strenuous work in heavy impermeable clothing.A preliminary experimental study examined the additional physiological stmn which protective clothing and a breathing apparatus produces in a fire fighter.Five professional fire fighters (mean age 33.2 + 5.8 years) completed two sub-maximal s a p tests in an environmental chamber at 40 OC and 70 % relative humidity, while wearing shorts (S) or protective clothing and a breathing apparatus (P).The data showed that protective clothing and a breathing apparatus significantly increase the physiological st& placed on a fire fighter.When wearing protective clothing subjects could not thennoregulate effectively and produced a mean rise in core temperature of 1.17 OC during exercise and recovery.This rise in core temperature was significantly (p 5 0.05) more than the 0.05 OC rise which occurred during work and recovery in shorts.A second study examined whether a more efficient cooling technique, interjected between work periods, can decrease the degree of heat stress during repetitive fire fighting activity.Twelve professional fire fighters (mean age 31.8 + 6.7 years) campleted two worldie~overy trids in an environiiental chamber at 40 OC and at 70 9 6 relative humidity.One trial was an optimal recovery (OR) trial and the other was a normal recovery (NR) trial.In both conditions a subject wore full protective clothing and a breathing apparatus during the work.In the OR trial subjects removed their protective coat and sat in front of a fan during botk recovery periods.In the Mi trial subjects merely unbuckled their coat and were not cooled by a fan during either recovery period.During the OR trial the group mean physiological responses were significantly lower (p 5 0.05).Core temperature increased by 1.5 OC in the NR trial but only by 0.8 OC during the OR trial.The results suggest that a more efficient cooling practice has the potential to reduce physiological strain and decrease the chance of heat exhaustion during repetitive fire fighting activity.The results also suggest that white a short exposure to heavy work in a hoi: environment wiii not endanger a heedthy fire fighterf tong term exposure will lead to a dangerous accumulation of heat stress and fatigue irrespective of physical prowess.
Source: Summit (Simon Fraser University)
Author: James Bruce Carter
Language: English
Subfield: Physiology (medical)
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2304915101