Leakage Inductance Calculation for Planar Transformers With a Magnetic Shunt
Year: 2014
Type: article
Abstract: The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance, which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the finite-element analysis simulation and the experimental results have proven the validity of the proposed calculation method for leakage inductance.
Language: English
Topic: Advanced DC-DC Converters
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
Funder: China Scholarship Council
OpenAlex ID: W2316013081